Title: Natural gas and propane installation code — originally published CAN/ CSA-B originally consisted of pages (xii preliminary and text). Several sections of the Canadian Standards Association B & B Natural Gas and. Propane Code require clarification. This Directive updates. 27 Nov Guest speaker Jeremy Salazar updated members on changes to CSA B, the Natural Gas and Propane Installation Code. Salazar.

Author: Teran Nitilar
Country: Bulgaria
Language: English (Spanish)
Genre: Marketing
Published (Last): 24 October 2015
Pages: 195
PDF File Size: 1.91 Mb
ePub File Size: 20.74 Mb
ISBN: 642-7-79860-937-1
Downloads: 59540
Price: Free* [*Free Regsitration Required]
Uploader: Murg

Changes to Section 7 in the edition affect the following sub-sections:.

Clde 3 of the Code provides definitions of terms used within the Code. Movable appliances where the connector is designed for repeated movement and disconnects or reconnection. Section 7 of the Code describes the requirements for specifics types of appliance installations. Changes to Section 6 in the edition affect the following sub-sections:. Changes to Section 7 in the edition affect the following sub-sections: Quick-disconnect Device The definition was expanded to address a disconnect device equipped with an automatic means to shut off the gas supply when the device is disconnected and is certified natrual ANSI Z Section 8 of the Code describes the requirements for venting systems and air supply for appliance installations.

The Codes are meant to replace the current Codes in use. Section 4 — General Section 4 of the Code describes the general requirements of propane and natural gas installations. Revisions to Clauses 6. The instaloation clause was found to be confusing and was rewritten for clarification.

CSA B149.1-15

Revision to Clause 7. Revision to Clause 6. Section antural — Venting systems and air supply for appliances Section 8 of the Code describes the requirements for venting systems and air supply for appliance installations.

Revision to Clauses 8. Gas Convenience Outlet new A permanently mounted certified hand-operated device that provides a means for connecting and disconnecting an appliance to the gas supply piping natudal way of a gas hose or gas connector.

  EL ORDEN CONSERVADOR NATALIO BOTANA PDF

Direct Gas-Fired Air Heaters new The new definition recognizes that a direct gas-fired air heater may be capable of either ventilation mode, to off-set building heat loss; or process mode, intended for drying, baking or curing product; or both operating modes. Changes to Section 8 in the edition affect the following sub-sections: Fordelene med et abonnement:.

Revisions to renumbered Clause 7. Section 6 of the Code describes the requirements for piping and tubing systems, gas hose, and fittings in natural gas and propane installations. Boiler An appliance intended to supply hot liquid or vapour for space-heating, processing, or power purposes and does not include appliances certified as water heaters. New editions of the Code were subsequently published in,, and The standard was originally developed for copper metallic press fittings but in the standard was revised to include other metallic materials copper, carbon steel and stainless steel.

Changes to Section 4 in the edition affect the following sub-sections: Revision to Clauses 7. When inspecting installations one must use the Code in existence at the time the installation was installed as Codes are generally not retroactive. This article, related to changes in version of B Revision to Clause 4. This definition recognizes check valve technology developed to prevent flue products backflow issues.

The following provides information related to references that have been changed or added. Notes to figures and tables, however, are considered part of the figure or table and may be written as mandatory requirements.

The purpose of a note is to separate from the text explanatory or informative material that is not properly a part of this Code. A person must use the most current Code rpopane in their Province or Territory for new or upgrading propane installations.

Revisions to Section 6.

This venting technology is currently permitted in Europe. Revisions to Clause 6. Les mer om abonnement. Section 5 — Pressure Controls Section 5 of the Code describes the requirements for pressure controls in natural gas and propane installations.

  HAROLDO DUTRA DIAS NOVO TESTAMENTO PDF

Section 5 of the Code describes the requirements for pressure controls in natural gas and propane installations. It snd a single source for appliance and gas system installations regardless of installed location. Changes to Section 6 in the edition affect the following sub-sections: Revision to Clause 8. Revisions to Clause 7.

Changes to Section 4 in the edition affect the following sub-sections:. The editions of the Codes are the completion of a 5-year code cycle that CSA uses to keep the Codes updated to address new technologies, new installation materials, and changing building environments. Gas connectors for outdoor use. There is a used market for these heaters pfopane they can still be functional, if naturall maintained, after 30 years. The committees who update the codes also consider changes to improve the usability of the document.

To be ibstallation, a value for the bb149.1-10 gas was inserted in the last row of Table 5. As a first step, B This amalgamation was in response to the trend among the authorities having jurisdiction of combining licensing and training for natural gas and propane. Under this agreement, CSA acquired the complete range of IAS standards administration, certification, and registration products and services for appliances and accessories fuelled by natural and liquefied petroleum gases.

Section 4 of the Code describes the general requirements of propane and natural gas installations. It is important to remember that an existing propane installation is considered to be in compliance if it still meets the requirements of the Code at the time of installation.